Attachment Name: Thin Film Pneumatic Fixture Attachment model: JDQA502A Maximum test force: 500N Joint size: φ 20 Clamping size: maximum opening size 6mm, jaw width 25mm, jaw glued. matters needing attention: Operating instructions: Firstly, connect the air circuit, connect the air source, adjust the pressure regulating valve to keep the air pressure between 0.5 and 0.8 Mpa, and lock it tightly. 2. Install the upper and lower fixtures onto the cross joint and fixture seat of the testing machine, insert the pins, and tighten the locking nuts. Step on the foot pedal pneumatic switch to control the opening and closing of the jaws, and install the sample properly. 4. Start the experiment. |